Application: High-voltage, High-temperature
Material: Composite Polymer
Structure: Cross-Arm Insulator
Samples:
US$ 30/Piece 1 Piece(Min.Order)
| Order Sample
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Composite Railway Insulator 25kv 16kn for Electric Railway Lines pictures & photos
Composite Railway Insulator 25kv 16kn for Electric Railway Lines
US $20-50 / Piece
Min. Order: 10 Pieces
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Hubei, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Overview
  • Product Description
  • Product Parameters
  • Raw Materials
  • Company Profile
  • Exhibition
  • Packaging & Shipping
  • Knowledge
Overview

Basic Info.

Model NO.
FQBG-25/16
Type
B Type Insulator
Usage
High Voltage Power Transmission, Insulation, Electrical Installation
Size of Bearing Capacity
16kn
Certification
ISO9001, ISO 14001, ISO 45001
Color
Gray, Red or Customized.
Brand
Line Power
Contract Manufacturing
OEM Service Offered
Business Type
Manufacturer, Trading Company
Rated Voltage
25kv
Creepage Distance
1600mm
Transport Package
Plywood Cases
Specification
800mm± 20mm
Trademark
Wuhan Line Power
Origin
Wuhan, China
HS Code
85469000
Production Capacity
4000pieces/Month/Machine

Packaging & Delivery

Package Size
1.00cm * 1.00cm * 1.00cm
Package Gross Weight
1.000kg

Product Description

Product Description
   At present, composite polymer tension insulators are widely used in power gridtransmission lines, accounting for about 50% of the line silicone rubber insulator consumption. Among them, the proportion of linear towers is higher. Almost all linear towers in heavily polluted areas use composite insulators. Composite polymeric insulators have solved the pollution flashover problem that has plagued the power grid for many years with their excellent anti-flashover performance.
Composite Railway Insulator 25kv 16kn for Electric Railway Lines

This series of products are composed of three parts: glass fiber epoxy resin drawing rod, silicone rubber umbrella skirt and metal fittings. The silicone rubber umbrella skirt adopts the whole injection and compression process, thus solving the key problem affecting the reliability of composite insulators -- the interface electrical breakdown.

The connection between the glass drawing rod and the metal fittings adopts the unique glue fitting technology, and adopts the most advanced pressing technology in China. It is equipped with the automatic sound wave flaw detection system with high strength, beautiful appearance, small volume and light weight. The metal fittings are galvanized to prevent corrosion and can be used interchangeable with ceramic insulators.

 
Product Parameters

Composite Railway Insulator 25kv 16kn for Electric Railway Lines

Rated Voltage
(kV)
Section Length
(mm)
Dry Arcing Distance
(mm)
Leakage Distance
(mm)
Power Frequency
Withstand Voltage
(kV)
Lightning Impulse
Withstand Voltage

(kV)
25 800±20 555 1600 190/150 310
 
Raw Materials

RAW MATERIALS:

End Fittings Core Sheds and Housing
Hot dip galvanized cast iron or cast steel Epoxy & Glass fiber(ECR is available) HTV Silicone Rubber
Min. thickness of the galvanization: 86μm Diameter(mm): Φ38, Φ40, Φ55, Φ70, Φ90, Φ120 Color: Grey, Red
 
Notes:
1. The color can be customized.
2. Below 220kV electrical data shown for composite line post insulators without corona rings and mounted vertically. Wuhan Line Power recommends corona rings to be installed at 220kV and above.
3. Additional section lengths and creepage distances are available. Contact sales agency for details.
4. All dimensions, tolerances and tests are within allowable IEC standards or ANSI standards.
5. All dimensions are in millimeters(mm). If in inches and pounds, please specify.
6. We can design according to the end user's requirements.

 
Company Profile

Our company with strong strength, reasonable price, good service and a number of enterprises to establish a long-term partnership.With high quality products and perfect after-sales service, we have won the consistent reputation of customers all over the country.We sincerely welcome customers from home and abroad to visit, investigate and discuss business cooperation.    
Composite Railway Insulator 25kv 16kn for Electric Railway Lines

Located in Wuhan, we implement ISO 9001: 2015 Quality Control, ISO14001: 2015 Environmental Management System, and ISO 45001: 2018 Occupational Health and Safety Management System. The company has more than 400 acres of land and has built six assembly line production workshops with a total of 8, 000 square meter of workshop space.

Composite Railway Insulator 25kv 16kn for Electric Railway Lines
All products are certified to international quality standards - IEC, ANSI, AS, BS, CAS, GB, and more.




Our company specializes in the production of composite insulators for transmission lines. The main structure is composed of rubber, epoxy glass fiber core and metal end fittings.
 

Composite Railway Insulator 25kv 16kn for Electric Railway Lines Composite Railway Insulator 25kv 16kn for Electric Railway Lines Composite Railway Insulator 25kv 16kn for Electric Railway Lines
Composite Railway Insulator 25kv 16kn for Electric Railway Lines Composite Railway Insulator 25kv 16kn for Electric Railway Lines Composite Railway Insulator 25kv 16kn for Electric Railway Lines


Compared with similar ceramic and glass insulators, silicone rubber insulators have the following advantages:

(1) Small size, light weight (1/7~1/10 times that of ceramic insulators with the same voltage), good elasticity of the shed, not easy to break, convenient transportation and installation, and economical.

(2) High mechanical strength. FRP rods have high tensile strength, which is 5-10 times that of ceramic materials. The cross-section of the core material is small, the product is small in size, light in weight, and high in tensile strength. It is easy to manufacture large-tonnage insulators above 300KN.

(3) High antifouling performance and good aging resistance. The silicone rubber injection molded shed has good hydrophobicity and mobility, which makes the insulator have high anti-pollution flashover voltage and good electrical corrosion resistance.


Composite Railway Insulator 25kv 16kn for Electric Railway Lines
(4) Easy installation and maintenance, which can greatly reduce maintenance costs caused by power outages and manual labor intensity.

(5) The production process is simple and the delivery time is short.

 

Exhibition

We have been participating in various exhibitions at home and abroad from 2010 to 2019. At the exhibition, relevant people from the industry and us saw our products directly and closely.

Composite Railway Insulator 25kv 16kn for Electric Railway Lines Composite Railway Insulator 25kv 16kn for Electric Railway Lines

 Inspection Before Shipment
 
Composite Railway Insulator 25kv 16kn for Electric Railway Lines
Before dispatched, the goods will be performed routine test and sample test comply with related standards. In case damage during the transportation, each one's sheds and housing will be checked thoroughly. Superficial defects of an area greater than 25 mm² (the total defective area not to exceed 0.2% of the total insulator surface) or of depth greater than 1mm.
Packaging & Shipping

1. All composite insulators are packed in weatherproof containers in order to protect the products during land, air, and sea transportation. Several different grades of packaging can be offered depending on the mode of transport and the expected storage conditions. The packaging options that we offer are
1) standard grade/prefabricated packing,
2) economical grade/cardboard carton, and
3) best grade/closed wooden crate.
Since the user best knows their crate requirements, they should select the option that is most suited to their needs and include that information in the purchasing specification. Special packaging arrangements can be accommodated upon request.


2. Each container is marked with the number of insulators it contains, the catalog number, the manufacturer's name, and any other customer requests.

3. Each packing (wooden Cases or Paper ubes) attached specification and certification of products.

 

Composite Railway Insulator 25kv 16kn for Electric Railway Lines Composite Railway Insulator 25kv 16kn for Electric Railway Lines
 
Knowledge

Analysis and preventive measures on insulator flashover of electrified high-speed railways

 

Catenary lines are an important part of electrified railways. They are erected in the open air along the lines and are affected by the natural environment and the surrounding operating environment. As an electrical insulation component of the catenary, the state of insulators directly affects the power supply of the catenary and the operation of electric locomotives and EMUs. Due to the existence of industrial pollution, the discharged dust falls with the wind and adheres to the contact network insulators, causing contamination on the surface of the insulators. In rain, snow, and foggy weather, pollution flashover occurs on the insulators under normal operating voltage, causing large-area and long-term damage. Timed power outage is one of the frequent accidents in electrified railways. Therefore, we should analyze the factors affecting the pollution flash discharge of insulators, understand the rules of pollution on the surface of insulators, strengthen insulation management and take targeted preventive measures to minimize the impact of pollution on electrified railways. transportation is of great significance.

 

 

Analysis of insulation pollution rules

 

There is a process of accumulation of dirt on the surface of insulators, which is directly related to the installation, suspension method and location of the insulator. As shown in Figure 1 below, the degree of contamination of the upstream and downstream insulators in the same section is different, and the degree of contamination of the insulators with additional suspended, flat, and oblique arm arms on the same pillar is also different, resulting in the oblique arm arm. There are differences in the flashover of insulators with flat wrist arms and additional suspension under the same voltage.

 

1. Different analysis of contamination on upstream and downstream insulators

In the double-track electrified railway section, the pollution source is on one side of the line. When the wind blows from the side of the pollution source to the line, the rod insulators installed in the upper and lower rows will have a row of insulator umbrella groups smoothly facing each other due to different installation methods. In the direction where the wind is blowing, the other row of insulators has the grooved side of the umbrella group facing the direction of the wind. The relatively smooth surface of the umbrella group with grooves is more likely to cause dust pollution to accumulate in the long term. This has caused one row of insulators to be dirty relative to the other row, and the density of salt attached to the surface of the insulators has also increased accordingly, resulting in a large area of fog flash tripping for one row of insulators in bad weather such as fog and snow, affecting power supply and driving.

2. Different analysis of contamination on flat and inclined insulators

In the triangular structure of the wrist arm installation, the angle between the oblique wrist arm insulator and the pillar is generally 60? During installation, the flat arm insulator is installed perpendicularly to the pillar. When the wind blows over with polluted dust, the windward area of the inclined arm insulator is approximately one-half of the surface area of the rod insulator, 0.40m? , the windward area of the flat wrist arm insulator is one-ninth of the surface area of the rod insulator, which is 0.07m? . Comparing the windward area, the area of angled arm insulators is nearly five times that of flat arm insulators, so insulators with angled arms are more likely to accumulate dirt than insulators with flat arms. As a result, insulators with oblique wrist arms have a higher chance of fog flash in bad weather such as fog and snow. The additionally suspended insulator is in a vertical state. Compared with the insulator with an inclined arm, the installation angle of the inclined arm is more likely to cause dust to fall and accumulate.

 

 

On-site data statistics and test analysis

 

On February 22, 2012, heavy fog with visibility less than 20 meters occurred on the Beijing-Shanghai High-Speed Railway between Tianjin South and Cangzhou West. A total of 7 catenary tripping occurred. The fault points were mainly distributed between K145+887 and K163+887. The fault point distribution indefinite. Through the work area, the site was inspected under the bridge, the rail car was inspected online, and the work area personnel were inspected on the high-speed train. No obvious fault points were found. Combined with the foggy weather with visibility less than 20m at the time, it was initially determined that the cause of the trip was a large area of insulator fog flash leakage that caused the trip. The skylight inspection revealed 7 insulator flashovers, including 6 oblique wrist arms and 1 flat wrist arm. The flashover insulators were all downward. Analysis and testing based on on-site inspection conditions are as follows:

(1) Conduct a salt density test on the replaced flashover insulator. The test value is 0.12mg/-0.13mg/. A heavily polluted area with a salt density of 0.1-0.3mg/ is used to determine the area where the flashover insulator is located. This section is a heavily polluted area.

(2) Through investigation, it was found that the pollution source (brick factory, steel plant industrial park, etc.) is on the downstream side of the flashover section. The oblique wrist arms on the up and downsides are at an angle of 60 degrees with the pillars. When the wind blows from the downward side to the upstream side, the contact area of the oblique wrist arms with the pollution source is larger than that of the flat wrist arms. Therefore, the dust fall area of the oblique wrist arms is larger and the dirt accumulation ratio is larger. Flat-wrist insulators are easier to use and accumulate more dirt. At the same time, when encountering heavy rain, both the upper and lower sides of flat-wrist insulators can be washed away by rainwater. Their self-cleaning properties are better than those of oblique-arm insulators, so oblique-arm insulators are better than flat-arm insulators. The arm is prone to flashover.

(3) When pollutants blow over with the wind, the windward area of the downward inclined arm insulator is 0.40m? , is half the surface area of the insulator, and the groove side of the porcelain group is in the direction of wind blowing, which is more likely to cause the accumulation of contaminated dust; the wind blowing area of the upward side inclined wrist arm insulator is less than 0.07m due to the installation angle? , and the surface of the porcelain group is facing the direction of the wind, and compared with the downward insulator, the degree of pollution accumulated by the polluted dust is smaller, so the pollution on the downward side is more serious than that on the upward side.

(4) The air humidity is relatively high in late winter and early spring. In foggy weather, there are water droplets on the surface of the insulator. On-site observation found that the water droplets formed on the surface of the flat wrist arm insulator dripped on the oblique wrist arm insulator, and at the same time, the flat wrist arm insulator The pollutants in the arm insulators are superimposed on the oblique arm insulators, which reduces the insulator's resistance to pollution lightning voltage, causing oblique arm insulators to be more prone to pollution flash tripping than flat arm insulators.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Composite Railway Insulator 25kv 16kn for Electric Railway Lines pictures & photos
Composite Railway Insulator 25kv 16kn for Electric Railway Lines
US $20-50 / Piece
Min. Order: 10 Pieces
Diamond Member Since 2022

Suppliers with verified business licenses

Secured Trading Service
Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
102
Year of Establishment
2008-07-03