Silicone Rubber Insulator for Power Transmission & Distribution

Product Details
Customization: Available
Application: High-voltage
Material: Composite Polymer
Still deciding? Get samples of US$ 8/Piece
Request Sample
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Silicone Rubber Insulator for Power Transmission & Distribution
Find Similar Products
  • Overview
  • Product Parameters
  • Product Description
  • Detailed Photos
  • Company Profile
  • Certifications
  • Packaging & Shipping
  • Exihibition
  • FAQ
Overview

Basic Info.

Model NO.
FXBW-52/120
Structure
Suspension Insulator
Type
B Type Insulator
Usage
High Voltage Power Transmission, Insulation, Electrical Installation
Connection Method
Spherical Type
Size of Bearing Capacity
120kn
Certification
ISO9001
Color
Grey, Red, Customized
Brand
Line Power
Rated Voltage
11kv,33kv,45kv,66kv,110kv,138kv,220kv,Custonmized
Contract Manufacturing
OEM Service Offered
Business Type
Manufacturer, Trading Company
Transport Package
Plywood Cases, Solid Wood Cases or Carton Boxes.
Specification
Customized
Trademark
Line Power
Origin
Wuhan, China
HS Code
85469000
Production Capacity
7000pieces/Month/Machine

Product Description

Silicone Rubber Insulator for Power Transmission & Distribution
At present, composite polymer tension insulators are widely used in power gridtransmission lines, accounting for about 50% of the line silicone rubber insulator consumption. Among them, the proportion of linear towers is higher. Almost all linear towers in heavily polluted areas use composite insulators. Composite polymeric  insulators have solved the pollution flashover problem that has plagued the power grid for many years with their excellent anti-flashover performance.
 
Product Parameters

Silicone Rubber Insulator for Power Transmission & Distribution
AC Composite Suspension Insulator

NO. Description Rated
Voltage
(kV)
Specified Mechanical Tensile Load (kN) Coupling Size Section Height
H (mm)
Minimum Nominal Arcing Distance
H (mm)
Minimum Nominal Creepage DistanceL (mm) Lightning Impulse Withstand Voltag≥(kV) Wet Switching Impulse Withstand Voltage≥(kV) Wet Power Frequency Withstand Voltage≥(kV)
1 FXBW-11/70 11 70 16 400±5 230 630 110 - 40
2 FXBW-11/100 11 100 16 400±5 228 630 110 - 40
3 FXBW3-33/70 33 70 16 610±15 445 1100 240 - 100
4 FXBW4-33/70 33 70 16 650±15 484 1140 240 - 100
5 FXBW-33/100(120) 33 100(120) 16 650±15 454 1285 240 - 100
6 FXBW3-66/70 66 70 16 870±15 710 2100 410 - 185
7 FXBW4-66/70 66 70 16 940±15 750 2170 410 - 185
8 FXBW-66/100(120) 66 100(120) 16 940±15 750 2420 410 - 185
9 FXBW3-110/70 110 70 16 1180±15 1024 3310 550 - 230
10 FXBW4-110/70 110 70 16 1240±15 1084 3370 550 - 230
11 FXBW3-110/100(120) 110 100(120) 16 1180±15 1004 3260 550 - 230
12 FXBW4-110/100(120) 110 100(120) 16 1240±15 1054 3300 550 - 230
13 FXBW-110/300 110 300 24 1480±15 1123 3266 550 - 230
14 FXBW3-220/100(120) 220 100(120) 16 2150±30 1964 6400 1000 - 395
15 FXBW4-220/100(120) 220 100(120) 16 2240±30 2049 6650 1000 - 395
16 FXBW3-220/160(180) 220 160(180) 20 2150±30 1904 6810 1000 - 395
17 FXBW4-220/160(180) 220 160(180) 20 2240±30 1980 7100 1000 - 395
18 FXBW-220/210(240) 220 210(240) 20 2300±30 1979 7090 1000 - 395
19 FXBW-220/300 220 300 24 2350±30 2001 6905 1000 - 395
20 FXBW3-330/100(120) 330 100(120) 16 2930±40 2725 9660 1425 950 570
21 FXBW4-330/100(120) 330 100(120) 16 2990±40 2804 10120 1425 950 570
22 FXBW3-330/160(180) 330 160(180) 20 2930±40 2654 9033 1425 950 570
23 FXBW4-330/160(180) 330 160(180) 20 2990±40 2714 9250 1425 950 570
24 FXBW3-330/210(240) 330 210(240) 20 2930±40 2614 9150 1425 950 570
25 FXBW4-330/210(240) 330 210(240) 20 2990±40 2674 9200 1425 950 570
26 FXBW-330/300 330 300 24 2930±40 2579 8680 1425 950 570
27 FXBW3-500/100(120) 500 100(120) 16 4030±50 3805 13500 2050 1240 740
28 FXBW4-500/100(120) 500 100(120) 16 4450±50 4217 16600 2250 1240 740
29 FXBW3-500/160(180) 500 160(180) 20 4030±50 3714 13450 2050 1240 740
30 FXBW4-500/160(180) 500 160(180) 20 4450±50 4174 15100 2250 1240 740
31 FXBW3-500/210(240) 500 210(240) 20 4030±50 3714 13450 2050 1240 740
32 FXBW4-500/210(240) 500 210(240) 20 4450±50 4134 14850 2250 1240 740
33 FXBW3-500/300 500 300 24 4030±50 3639 12900 2050 1240 740
34 FXBW4-500/300 500 300 24 4450±50 4059 14150 2250 1240 740
35 FXBW3-500/400(420) 500 400 28 4030±50 3630 14832 2050 1240 740
36 FXBW4-500/530(550) 500 530 32 4450±50 3957 15300 2250 1240 740
37 FXBW-750/100(120) 750 100(120) 16 7150±50 6930 23500 2700 1800 740
38 FXBW-750/160(180) 750 160(180) 20 7150±50 6800 23500 2700 1800 740
39 FXBW-750/210(240) 750 210(240) 20 7150±50 6800 23500 2700 1800 740
40 FXBW-750/300 750 300 24 7150±50 6735 23500 2700 1800 740
41 FXBW-750/400(420) 750 400(420) 28 7150±50 6730 23500 2700 1800 740
42 FXBW-750/530(550) 750 530(550) 32 7150±50 6625 23500 2700 1800 740
43 FXBW-1000/160(180) 1000 160(180) 20 9500±50 9150 27500 2400 1800 1300
44 FXBW-1000/210(240) 1000 210(240) 20 9500±50 9150 27500 2400 1800 1300
45 FXBW-1000/300 1000 300 24 9500±50 9115 27500 2400 1800 1300
46 FXBW-1000/400(420) 1000 400(420) 28 9500±50 9075 27500 2400 1800 1300
47 FXBW-1000/530(550) 1000 530(550) 32 9500±50 8975 27500 2400 1800 1300
48 FXBW-1000/160(180)-S 1000 160(180) 20 9800±50 9200 27500 2400 1800 1300
49 FXBW-1000/210(240)-S 1000 210(240) 20 9900±50 9200 27500 2400 1800 1300
50 FXBW-1000/530(550)-S 1000 530(550) 32 10000±50 8950 27500 2400 1800 1300

DC Composite Suspension Insulator
NO. Description Rated
Voltage
(kV)
Specified Mechanical Tensile Load (kN) Coupling Size Section Height
H (mm)
Minimum Nominal Arcing Distance
H (mm)
Minimum Nominal Creepage DistanceL (mm) Lightning Impulse Withstand Voltag≥(kV) Wet Switching Impulse Withstand Voltage≥(kV) Wet Power Frequency Withstand Voltage≥(kV)
1 FXBZ-±400/160(180) ±400 160(180) 20 8000±50 7600 26000 2800 1800 750
2 FXBZ-±400/210(240) ±400 210(240) 20 8000±50 7600 26000 2800 1800 750
3 FXBZ-±400/300 ±400 300 24 8000±50 7600 26000 2800 1800 750
4 FXBZ-±400/400(420) ±400 400(420) 28 8000±50 7600 26000 2800 1800 750
5 FXBZ-±400/530(550) ±400 530(550) 32 8000±50 7500 26000 2250 1150 600
6 FXBZ-±500/160(180) ±500 160(180) 20 5440±50 5070 20500 2250 1550 600
7 FXBZ-±500/210(240) ±500 210(240) 20 5440±50 5070 20500 2250 1550 600
8 FXBZ-±500/300 ±500 300 24 5440±50 5040 20500 2250 1550 600
9 FXBZ-±500/400(420) ±500 400(420) 28 5440±50 4950 20500 2250 1550 600
10 FXBZ-±500/530(550) ±500 530(550) 32 5440±50 4900 20500 2250 1550 600
11 FXBZ-±500/160(180) ±500 160(180) 20 6000±50 5630 20500 2250 1550 600
12 FXBZ-±500/210(240) ±500 210(240) 20 6000±50 5630 20500 2250 1550 600
13 FXBZ-±500/300 ±500 300 24 6000±50 5600 20500 2250 1550 600
14 FXBZ-±500/400(420) ±500 400(420) 28 6000±50 5510 20500 2250 1550 600
15 FXBZ-±500/530(550) ±500 530(550) 32 6000±50 5500 20500 2250 1550 600
16 FXBZ-±660/160(180) ±660 160(180) 20 8500±50 8100 33400 2800 1800 750
17 FXBZ-±660/210(240) ±660 210(240) 20 8500±50 8100 33400 2800 1800 750
Notes:
1. The color can be customized.
2. Below 220kV electrical data shown for composite line post insulators without corona rings and mounted vertically. Wuhan Line Power recommends corona rings to be installed at 220kV and above.
3. Additional section lengths and creepage distances are available. Contact sales agency for details.
4. All dimensions, tolerances and tests are within allowable IEC standards or ANSI standards.
5. All dimensions are in millimeters(mm). If in inches and pounds, please specify.
6. We can design according to the end user's requirements.

 
Product Description

Raw Materials

Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
 
End Fittings Core Sheds and Housing
Hot dip galvanized cast iron or cast steel Epoxy & Glass fiber(ECR is available) HTV Silicone Rubber
Min. thickness of the galvanization: 86μm Diameter(mm): Φ38, Φ40, Φ55, Φ70, Φ90, Φ120 Color: Grey, Red
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
 
Detailed Photos
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution

 

Company Profile
Silicone Rubber Insulator for Power Transmission & Distribution
Our company with strong strength, reasonable price, good service and a number of enterprises to establish a long-term partnership. With high quality products and perfect after-sales service, we have won the consistent reputation of customers all over the country. We sincerely welcome customers from home and abroad to visit, investigate and discuss business cooperation. 

Advanced Manufacturing Equipments
Silicone Rubber Insulator for Power Transmission & DistributionThe company holds the most advanced Automatic Silicone Injection Molding Machines and Voice-operated Displacement Crimping Machines which means the world's most advanced process technology level.

Sound Testing Equipment
Silicone Rubber Insulator for Power Transmission & Distribution
The company is equipped with 1000kV Power Frequency Testing Transformer, 1800kV Impulse Voltage Generator set and 2000kN Automatic Tensile Test Machine, as well as well-equipped Physical Laboratory and Electrical Laboratory.
 
Certifications
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Standards:
IEC 61109, ISO 9001, ISO 14001, ISO 45001. We can design products in accordance with Client's Requirements.

Silicone Rubber Insulator for Power Transmission & DistributionWe have implemented advanced management and set up a strict quality management system according 1- 1509001 : 200S. All the products' quality requirements comply with IEC61109, IEC62231, G3/T19519-2004,GE/T 22079-200s, DU/T 1048-2007.DL/T810-2002 and TE/T3199.2-200g Standards, etc.
 
Packaging & Shipping

1. All composite insulators are packed in weatherproof containers in order to protect the products during land, air, and sea transportation. Several different grades of packaging can be offered depending on the mode of transport and the expected storage conditions. The packaging options that we offer are
    1) standard grade/prefabricated packing
    2) economical grade/cardboard carton
    3) best grade/closed wooden crate

    Since the user best knows their crate requirements, they should select the option that is most suited to their needs and include that information in the purchasing specification. Special packaging arrangements can be accommodated upon request.

2. Each container is marked with the number of insulators it contains, the catalog number, the manufacturer's name, and any other customer requests.
3. Each packing (wooden Cases or Paper ubes) attached specification and certification of products.

Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution

 

Exihibition
Silicone Rubber Insulator for Power Transmission & Distribution
Silicone Rubber Insulator for Power Transmission & Distribution

We have been participating in various exhibitions at home and abroad from 2010 to 2020. At the exhibition, relevant people from the industry and us saw our products directly and closely.

FAQ

1. Q: Are you the factory or trading company?
A: We are factory who was founded in 2008. We also source all the items for the clients.

2. Q: What're your main products?
A: insulators, the hardware of all kinds for high-voltage applications and related products.
 

3. Q: Can I get some samples?
A: Yes, sample order is available for quality check and market test.
 

4. Q: What's your payment terms?
A: We usually accept :Payment Term: 30% T/T after order confirmed, balance 70% before shipment. L/C is also available.
 

5. Q: How can you control your quality? 
A: For each production processing, we have a complete QC system for the chemical composition, physical and electrical properties. After production, all the goods will be tested according to related standards, and the ex-factory test reports will be sent along with shipment documents.
   

6. Q: Does your company accept customization?
A: We accept OEM service.
 
7. Q: What's your warranty terms?
A: We offer 24 months warranty terms.
 
8. Q: Do you have the products in stock?
A: Depends on your request, we have standard models in stock. Some special product and big order will be newly produced according to your order.
 
9. Q: What do you have for the certificate?
A: ISO9001, ISO14001, ISO45001, Type test etc.
 
10. Q: How to become the agents for Line?
A: We welcome you to be Line's agent. 
We will depend on the sales turn over and also do research on your market. If you have interest, let us discuss more!
 
11.Q: Can we visit your company?
A: Yes, for sure, you are welcome to visit our company.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier