Silicone Rubber High Voltage Power Line Insulators for Substation

Product Details
Customization: Available
Application: High-voltage, High-temperature
Material: Composite Polymer
Still deciding? Get samples of US$ 170/Piece
Order Sample
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Manufacturer/Factory & Trading Company

360° Virtual Tour

Secured Trading Service
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Silicone Rubber High Voltage Power Line Insulators for Substation
  • Silicone Rubber High Voltage Power Line Insulators for Substation
  • Silicone Rubber High Voltage Power Line Insulators for Substation
  • Silicone Rubber High Voltage Power Line Insulators for Substation
  • Silicone Rubber High Voltage Power Line Insulators for Substation
  • Silicone Rubber High Voltage Power Line Insulators for Substation
Find Similar Products
  • Overview
  • Product Description
  • FEATURES:
  • Company Profile
  • Exhibition
  • Certifications
  • Packaging & Shipping
  • FAQ
Overview

Basic Info.

Model NO.
FZSW-35
Structure
Post Insulator
Type
Horizontal- Base
Usage
High Voltage Power Transmission, Insulation, Electrical Installation
Connection Method
Spherical Type
Size of Bearing Capacity
12kN
Certification
ISO9001, ISO 14001, ISO 45001
Color
Gray, Red or Customized.
Brand
Line Power
Contract Manufacturing
OEM Service Offered
Custmoize
Available
Stanard
IEC & ANSI
MOQ
None
Transport Package
Plywood Cases
Trademark
Line Power
Origin
Wuhan, China
HS Code
85469000
Production Capacity
4000pieces/Month/Machine

Packaging & Delivery

Package Size
100.00cm * 30.00cm * 30.00cm
Package Gross Weight
4.000kg

Product Description

Silicone Rubber High Voltage Power Line Insulators for Substation
 
Product Description
 Composite Line Post Insulators are essential to the safe and stable distribution of electricity generated at power plants. The power line insulator found in power handling equipment at power plants and substations support electric cables and other equipment, isolating them from the ground.
Silicone Rubber High Voltage Power Line Insulators for Substation

The  Composite Line Post Insulator support each piece of equipment; several can be connected to form an insulator column.

Silicone Rubber High Voltage Power Line Insulators for Substation
Payment & Shipping Terms:

Type: Composite Post Insulator
Minimum Order Quantity: 100 pcs
Price: Negotiable
Packaging Details: plywood case, fumigated solid wood case
Delivery Time: 45~50 days EX-works
Standard: IEC 62231, ANSI C29.1

RAW MATERIALS:
End Fittings Core Sheds and Housing
Materials: Hot dip galvanized cast iron or cast steel Epoxy & Glass Fiber HTV Silicone Rubber
Min. thickness of the galvanization: 86μm Rod Diameter: Φ70mm Color: Red or Grey


Notes:
1. All section lengths are based on vertical & base or bolt end fittings.
2. Below 220kV electrical data shown for composite line post insulator without corona rings and mounted vertically. Wuhan Line Power recommends corona rings to be installed at 220kV and above.
3. Additional section lengths and creepage distances are available. Contact sales agency for details.
4. All dimensions, tolerances and tests are within allowable IEC standards or ANSI standards.
5. All dimensions are in millimeters(mm). If in inches and pounds, please specify.
6. We can design according to the end user's requirements.
 
FEATURES:

 

  1. The silicone rubber housing of Composite Line Post Insulator were taken shape by whole injection. It has good hydrophobicity, hydrophobicity migration and soil resistance, as well as excellent electrical insulation properties and aging resistance, which could prevent effectively those accidents of pollution flashover so as to ensure the safe running of high voltage transmission lines. 
  2. The modified ECR fiberglass reinforced epoxy resin rod is used as it has good resistance to high temperature, stess corrosion & acid attack, as well as fine damping action, high tensile strength (> 1200Mpa) and resistance to creep and fatigue failure, which effectively ensure the internal insulation quality and mechanical stength of insulators.
  3. End fittings are crimped onto fiberglass rod with voice-operated displacement type crimper. The insulators with this crimping technique have high mechanical strength and small dispersion. Taking the most advanced automatic overall injection moulding technic and connection method of crimping for production and assembling, and the whole crimping procedure controlled by computer and the crimping result monitored by ultrasonic detector to assure each product is qualified.
Silicone Rubber High Voltage Power Line Insulators for Substation
 

Item

Requirement

Measured Valued

Visual examination

Fuchsine,grey or white,
 no obvious mechanical admixture. 
Vulcanized sillion rubber 
with dense and smooth cutting surface.

Ok

Hardness (shore A)

50

65~70

Tensile strength  (Map)

4

4~6

Failure elongation  (%)

150

180

Tearing strength (kN/m)

10 (right angle sample)

12~15

Volume resistivity (Ω.m)

1X1012

3~8X1012

Puncture strength (kV/mm)

Alternating current ≮22

30

Tracking and erosion

TMA4.5,erosion depth≯2.5mm

TMA4.5, erosion depth <0.8mm

Flammability (Grade)

FV-0

FV-0

Company Profile

Our company with strong strength, reasonable price, good service and a number of enterprises to establish a long-term partnership.With high quality products and perfect after-sales service, we have won the consistent reputation of customers all over the country.We sincerely welcome customers from home and abroad to visit, investigate and discuss business cooperation.    
Silicone Rubber High Voltage Power Line Insulators for Substation


 

Silicone Rubber High Voltage Power Line Insulators for Substation
Sound Testing Equipment
The company is equipped with 1000kV Power Frequency Testing Transformer, 1800kV Impulse Voltage Generator set and 2000kN Automatic Tensile Test Machine, as well as well-equipped Physical Laboratory and Electrical Laboratory.





Advanced Manufacturing Equipments
The company holds the most advanced Automatic Silicone Injection Molding Machines and Voice-operated Displacement Crimping Machines which means the world's most advanced process technology level.





Our company specializes in the production of composite insulators for transmission lines. The main structure is composed of rubber, epoxy glass fiber core and metal end fittings.

Silicone Rubber High Voltage Power Line Insulators for Substation Silicone Rubber High Voltage Power Line Insulators for Substation
   
   



Compared with similar ceramic and glass insulators, silicone rubber insulators have the following advantages:

(1) Small size, light weight (1/7~1/10 times that of ceramic insulators with the same voltage), good elasticity of the shed, not easy to break, convenient transportation and installation, and economical.

(2) High mechanical strength. FRP rods have high tensile strength, which is 5-10 times that of ceramic materials. The cross-section of the core material is small, the product is small in size, light in weight, and high in tensile strength. It is easy to manufacture large-tonnage insulators above 300KN.

(3) High antifouling performance and good aging resistance. The silicone rubber injection molded shed has good hydrophobicity and mobility, which makes the insulator have high anti-pollution flashover voltage and good electrical corrosion resistance.

(4) Easy installation and maintenance, which can greatly reduce maintenance costs caused by power outages and manual labor intensity.

(5) The production process is simple and the delivery time is short.

Exhibition

We have been participating in various exhibitions at home and abroad from 2010 to 2019. At the exhibition, relevant people from the industry and us saw our products directly and closely.

Silicone Rubber High Voltage Power Line Insulators for Substation

Certifications
 
We have implemented advanced management and set up a strict quality management system according 1- 1509001 : 200S. All the products' quality requirements comply with IEC61109, IEC61952, IEC62231, G3/T19519-2004,GE/T 22079-200s, DU/T 1048-2007.DL/T810-2002 and TE/T3199.2-200g Standards, etc
 
Silicone Rubber High Voltage Power Line Insulators for Substation
Packaging & Shipping

 

1. All composite insulators are packed in weatherproof containers in order to protect the products during land, air, and sea transportation. Several different grades of packaging can be offered depending on the mode of transport and the expected storage conditions. The packaging options that we offer are
1) standard grade/prefabricated packing,
2) economical grade/cardboard carton, and
3) best grade/closed wooden crate.
Since the user best knows their crate requirements, they should select the option that is most suited to their needs and include that information in the purchasing specification. Special packaging arrangements can be accommodated upon request.


2. Each container is marked with the number of insulators it contains, the catalog number, the manufacturer's name, and any other customer requests.

3. Each packing (wooden Cases or Paper ubes) attached specification and certification of products.
Silicone Rubber High Voltage Power Line Insulators for Substation

FAQ

1. Q: Are you the factory or trading company?
A: We are factory who was founded in 2008. And we also source all the items for the clients.

2. Q: What're your main products?
A: insulators, the hardware of all kinds for high-voltage applications and related products.
 
3. Q: Can I get some samples?
A: Yes, sample order is available for quality check and market test.
 
4. Q: What's your payment terms?
A: We usually accept :Payment Term: 30% T/T after order confirmed, balance 70% before shipment. And L/C is also be available.
 
5. Q: How can you control your quality? 
A: For each production processing, we have a complete QC system for the chemical composition, physical and electrical properties. After production, all the goods will be tested according to related standards, and the ex-factory test reports will be sent along with shipment documents.
   
6. Q: Does your company accept customization?
A: We accept OEM service.
 
7. Q: What's your warranty terms?
A: We offer 24 months warranty terms.
 
8. Q: Do you have the products in stock?
A: Depends on your request, we have standard models in stock. Some special product and big order will be newly produced according to your order.
 
9. Q: What do you have for the certificate?
A: ISO9001, ISO14001, ISO45001, Type test etc.
 
10. Q: How to become the agents for Line?
A: We welcome you to be Line's agent. 
We will depend on the sales turn over and also do research on your market. If you have interest, let us discuss more!
 
11.Q: Can we visit your company?
A: Yes, for sure, you are welcome to visit our company.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now