Station Post Insulator 69kv for Power Transmission & Distribution

Application: High-voltage, High-temperature
Material: Composite Polymer
Structure: Post Insulator
Type: B Type Insulator
Usage: High Voltage Power Transmission, Insulation, Electrical Installation
Connection Method: Flangs
Samples:
US$ 10/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Manufacturer/Factory & Trading Company

360° Virtual Tour

Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Hubei, China
Cooperated with Fortune 500
This supplier has Cooperated with Fortune 500 companies
Standardized quality control
The supplier has a complete and standardized quality control process, check the Audit Report for more information
R&D Capabilities
The supplier has 4 R&D engineers, you can check the Audit Report for more information
Production Process Visualization
You can check the supplier's production workflow chart or main facilities in the Audit Report
to see all verified strength labels (27)
  • Overview
  • Product Description
  • Product Parameters
  • Certifications
  • Packaging & Shipping
  • Company Profile
Overview

Basic Info.

Model NO.
FZSW-69/26.8
Size of Bearing Capacity
26.8kn
Certification
ISO9001
Color
Gray, Red, Customized
Brand
Wuhan Line Power
Weight
17.8kg
Transport Package
Plywood Case
Specification
814mm
Trademark
Customized
Origin
China
HS Code
8546900000
Production Capacity
7000PCS/Month/Machine

Product Description

Composite Station Post Insulators

Product Description
Station Post Insulator 69kv for Power Transmission & Distribution
Insulators are used to support and fix the bus and the live conductor, and make the live conductor or conductor and the earth have enough distance and
Insulation.Insulators shall have sufficient electrical insulation strength and moisture resistance.

In order to prevent pollution such as floating dust from attaching to the insulator surface, a path is formed to be broken down by the voltage at both ends of the insulator, namely creepage. Therefore, increasing the surface distance is creep distance, and the discharge distance along the insulation surface is leakage distance, which is creep distance.
 
Product Parameters
 

TECHNICAL DATA:
Station Post Insulator 69kv for Power Transmission & Distribution

Model System Voltage
(kV)
Height
(mm)
Dry Arcing Distance
(mm)
Creepage Distance
(mm)
Specified Cantilever Load
(SCL)
Max. Working Cantilever Load
(MDCL)
Power Frequency Withstand Voltage
(Wet/Dry)
Lightning Impulse Withstand Voltage
FZSW-69/26.8 69 814±10 660 1895 26.8kN 12kN 170kV/200kV 385kV
 
Station Post Insulator 69kv for Power Transmission & Distribution
Station Post Insulator 69kv for Power Transmission & Distribution
Station Post Insulator 69kv for Power Transmission & Distribution
Station Post Insulator 69kv for Power Transmission & Distribution


Technology characteristics:
  • Silicone Rubber Housing
    Better hydrophobicity
    Better hydrophobicity migration performance
    Better pollution resistance
    Excellent electrical insulation properties
    Excellent aging resistance

 
Item Requirement Measured Valued
Visual examination Fuchsine, grey or white, no obvious mechanical admixture. Vulcanized silicon rubber with dense and smooth cutting surface. Ok
Hardness (shore A) ≮50 65~70
Tensile strength (Map) ≮4 4~6
Failure elongation (%) ≮150 ≮180
Tearing strength (kN/m) ≮10 (right angle sample) 12~15
Volume resistivity (Ω.m) 1X1012 3~8X1012
Puncture strength (kV/mm) Alternating current ≮22 ≮30
Tracking and erosion TMA4.5,erosion depth≯2.5mm TMA4.5, erosion depth <0.8mm
Flammability (Grade) FV-0 FV-0
 
  • Corrosive Resistance Fiberglass Core
    Excellent resistance to high temperature, stress corrosive & acid attack
    Better damping Performance
    High tensile strength (
    >1200Mpa)
    Excellent creep resistance
    Excellent anti-fatigue fracture properties
 
  • Crimping & Multiple Sealing
    High mechanical strength
    Small dispersion
    Reliable sealing performance between rods and end fittings
Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution
  
Certifications

STANDARDS:
IEC 62231, ISO 9001, ISO 45001, ISO 14001, etc. We can design products in accordance with Client's Requirements.

Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution
Packaging & Shipping

PACKAGING

Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution

All insulators are packed in weatherproof containers in order to protect the products during land, air and sea transportation. Several different grades of packaging can be offered depending on the mode of transport and the expected storage conditions. Special packaging arrangements can be accommodated upon the users' request. 

Company Profile

About US
Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution

Wuhan Line Power transmission and transformation co., LTD. Mainly produces and sells composite insulators and accessories. Is a collection of manufacturing, processing, distribution and other business as one of the manufacturing company. The company is based on the r&d, manufacturing and sales of the complete set of composite insulator equipment.With excellent product quality, reasonable price and good service for the enterprise, won the majority of customers praise and trust.

Factory Direct
 
Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution
 
Station Post Insulator 69kv for Power Transmission &amp; Distribution
Station Post Insulator 69kv for Power Transmission &amp; Distribution

Quality Control:
Station Post Insulator 69kv for Power Transmission &amp; Distribution

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company
Number of Employees
102
Year of Establishment
2008-07-03